STRINGER 27L SPLICE HAS CORROSION BETWEEN FS 333-FS 349. REMOVED CORRODED INTERCOSTAL, LOCATED AND DRILLED NEW INTERCOSTAL, INSTALLED AND FINISHED PER SRM 51-42-06-001-001-A01, 51-40-11-001-001-A01, 51-42-06-001-001-A01.