What was found
CORROSION FOUND ON THE FLOORBEAM ANGLE BS 280 BETWEEN LBL 9 AND RBL 9. R & R THE FLOORBEAM ANGLE IAW SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01, & 51-40-11-001-001-A01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON THE FLOORBEAM ANGLE BS 280 BETWEEN LBL 9 AND RBL 9. R & R THE FLOORBEAM ANGLE IAW SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01, & 51-40-11-001-001-A01.