What was found
FS 265 FRAME, STR 26L - 26R CORRODED. EVALUATED DAMAGE AND DETERMINED CORROSION TO BE CONTAINED TO STIFFENING ANGLE AT FS 265. DAMAGE IS OUT OF LIMITS. REF SRM 53-00-00-101-001 A01. REMOVED STIFFENING ANGLE REF SRM 51-42-06-001-001 A01. DRILLED UP NEW STIFFENING ANGLE REF SRM 54-40-11-001-001 A01. INSTALLED NEW, SERVICEABLE STIFFENING ANGLE IAW SRM 51-42-06-001-001 A01, 51-23-00-001-001 A01, DWG CC670-33025 & DWG CC670-34-020. RESTORED FINISH AND CIC REF SRM 51-25-16-001-001 A01 & 51-21-11-001-001 A01.