What was found
UPON REMOVAL OF STRINGER 26R FOUND CRACK DAMAGE ON FRAME FS333 LOWER FLANGE BETWEEN STRINGER 26R AND STRINGER 25R. CUT OUT FRAME FLANGE IAW REO 670-53-21-1281. PERFORMED EDDY CURRENT INSPECTION OF CUT EDGES IAW NDTM PT 1, 51-20-006-250-A01. FABRICATE REPAIR PARTS IAW SRM 51-24-21-001-001-A01, 51-24-36-001-001-A01. DRILLED FASTENER HOLES AND INSTALLED FASTENERS IAW SRM 51-42-001-001-A01. COMPLIED WITH EC/TC REO 670-53-21-1281 AND GENERIC REO 670-53-21-1281 REV--, DATED: 04/11/2016 AS WRITTEN.