What was found
DURING INSPECTION, A CREASED DENT WAS FOUND AT FRAME 4 ABOVE STRINGER 17L. MEASUREMENTS ARE L=3.5", W=3.25", D=.005". DAMAGE WAS CUT OUT AND A DOUBLER REPAIR WAS APPLIED PER ETD2018-145-040730.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, A CREASED DENT WAS FOUND AT FRAME 4 ABOVE STRINGER 17L. MEASUREMENTS ARE L=3.5", W=3.25", D=.005". DAMAGE WAS CUT OUT AND A DOUBLER REPAIR WAS APPLIED PER ETD2018-145-040730.