What was found
CENTER LAVATORY FLOOR OMEGA BEAM CORRODED THROUGH NUT PLATE HOLE AT FRAME 59. CORRECTIVE ACTION: REPAIRED CENTER LAVATORY FLOOR OMEGA BEAM NUT PLATE AT FRAME 59 IAW SRM 53-24-10, REPAIR TYPE 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CENTER LAVATORY FLOOR OMEGA BEAM CORRODED THROUGH NUT PLATE HOLE AT FRAME 59. CORRECTIVE ACTION: REPAIRED CENTER LAVATORY FLOOR OMEGA BEAM NUT PLATE AT FRAME 59 IAW SRM 53-24-10, REPAIR TYPE 3.