What was found
DURING MX INSPECTION THE EMERGENCY SIGN IN FRONT OF 3C WAS INOP.MX REMOVED BAD #3 INVERTER AND INSTALLED NEW INVERTER IAW EMB145 AMMII 33-50-11, OPS CHECK GOOD A/C WAS APPROVED FOR RETURN TO SERVICE
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING MX INSPECTION THE EMERGENCY SIGN IN FRONT OF 3C WAS INOP.MX REMOVED BAD #3 INVERTER AND INSTALLED NEW INVERTER IAW EMB145 AMMII 33-50-11, OPS CHECK GOOD A/C WAS APPROVED FOR RETURN TO SERVICE