What was found
ON APPROACH ATL-FAY, SELECTED TO 15 DEG,THE I/B AND NACELLE FLAPS TRACKED TO 15 DEG WHILE THE O/B PAIR ON THE LT SIDE STOPPED AT 5 DEG'S, THE RT SIDE INDICATED 45 DEG'S. A POSITIVE ROLL WAS FELT. THE CREW PROCEEDED WITH THE ASSEMETRY CHECKLIST, DECLARED AN EMERGENCY AND LANDED FAY WITHOUT FURTHER INCIDENT. LOCAL MX INSPECTED THE A/C AND FOUND SAFE FOR A ZERO-FLAP FERRY FLT TO ATL. ATL MX CYCLED THE FLAPS 30 TIMES AND COULD NOT DUPLICATE THE PROBLEM. AS A PREVENTIVE MEASURE, REMOVED AND REPLACED THE COMPUTER. THE FLAPS WERE THEN CYCLED ANOTHER 15 TIMES WITH NO DEFECTS NOTED. THE A/C WAS RELEASED FOR FURTHER SERVICE. (M)