What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND AFT PIT AT BS 965 LS 23 FRAME CORRODED. REMOVED AND REPLACED CORRODED SECTION OF FRAME WITH NEW FRAME AT BS 965 LS 23 IAW DC9 SRM 51-30-02, 51-30-05, 51-10-04, 53-03 FIG 2A, AND 51-30-01.