What was found
FOUND FLOOR SUPPORT AT BS 197 BL 0 TO LBL 44 HAD EXFOLIATION CORROSION. REMOVED FLOOR SUPPORT, FABRICATED, TRIMMED, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED NEW SUPPORT IAW DC9 SRM 51-10-4, 53-11-1 FIG 13, 51-10-3 AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOOR SUPPORT AT BS 197 BL 0 TO LBL 44 HAD EXFOLIATION CORROSION. REMOVED FLOOR SUPPORT, FABRICATED, TRIMMED, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED NEW SUPPORT IAW DC9 SRM 51-10-4, 53-11-1 FIG 13, 51-10-3 AND 51-30-2.