What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND G-1 GALLEY CENTER OUTBOARD COMPARTMENT LOWER OUTBOARD SLIDE BRACKET CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED REPLACEMENT SLIDE BRACKET IAW DC9 SRM 51-10-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND G-1 GALLEY CENTER OUTBOARD COMPARTMENT LOWER OUTBOARD SLIDE BRACKET CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED REPLACEMENT SLIDE BRACKET IAW DC9 SRM 51-10-02.