DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOOR SUPPORT CORRODED ON BOTH SIDES AT BS 200, RBL 44 - 56. CORRECTIVE ACTION: FABRICATED AND INSTALLED NEW SUPPORT IAW DC SRM53-01 FIG 1, 51-10-02, AND 51-10-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOOR SUPPORT CORRODED ON BOTH SIDES AT BS 200, RBL 44 - 56. CORRECTIVE ACTION: FABRICATED AND INSTALLED NEW SUPPORT IAW DC SRM53-01 FIG 1, 51-10-02, AND 51-10-03.