What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND DENTS, AT BS 1153, LONGERON 6 - 7 RT AND BS 1155, LONGERON 5 - 6 RT, BEYOND LIMITS. CORRECTIVE ACTION: REMOVED AND INSTALLED NEW SKIN IAW REO-L00110 AND DC9 SRM 51-10-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND DENTS, AT BS 1153, LONGERON 6 - 7 RT AND BS 1155, LONGERON 5 - 6 RT, BEYOND LIMITS. CORRECTIVE ACTION: REMOVED AND INSTALLED NEW SKIN IAW REO-L00110 AND DC9 SRM 51-10-04.