What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LOWER WEB AT BS 965 TO HAVE LEVEL 2 EXFOLIATION CORROSION. INSTALLED NEW WEB IAW DC9 SRM 51-10-04, 53-11-03, 51-10-03, AND 51-10-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LOWER WEB AT BS 965 TO HAVE LEVEL 2 EXFOLIATION CORROSION. INSTALLED NEW WEB IAW DC9 SRM 51-10-04, 53-11-03, 51-10-03, AND 51-10-02.