What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CABIN FLOOR SUPPORT AT BS 165-230 BL 0 TO HAVE LEVEL 2 CORROSION. INSTALLED NEW FLOOR SUPPORT AT BS 165 - 230 BL 0 IAW DC9 SRM 53-11-01, 51-10-02, 51-10-03, 51-10-04, AND 51-30-05.