What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND END CAP AT BS 598 CORRODED. AFTER CORROSION REMOVAL FOUND OUT OF LIMITS. REMOVED AND REPLACED WITH NEW END CAP IAW DC9 SRM 51-10-04, 51-10-03, 51-30-02, AND 51-30-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND END CAP AT BS 598 CORRODED. AFTER CORROSION REMOVAL FOUND OUT OF LIMITS. REMOVED AND REPLACED WITH NEW END CAP IAW DC9 SRM 51-10-04, 51-10-03, 51-30-02, AND 51-30-01.