DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND RIGHT MAIN TANK TEE CAP TO HAVE CORROSION BEYOND LIMITS FROM STRINGER 11 TO STRINGER 23. REMOVED AND REPLACED RIGHT TEE CAP IAW DC9 SB 57-98.