SDR AT0000208

Service difficulty report · Psu · Doug DC932

Difficulty date
April 14, 2000
Submitted
April 25, 2000
Operation
Air carrier
Aircraft
N836AT
Make and model
Doug DC932
Aircraft serial
47397
Part
Psu
Part number
592886510
Part serial
97448
Condition
Malfunctioned
Location
Row 26
Stage of operation
CR
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CRUISE LEFT PACK TURNED OFF, RIGHT PACK WOULD NOT HOLD CABIN ALTITUDE. CABIN MASKS DROPPED. RIGHT HAND PRESSURE LINE TO PRESSURE REGULATOR CAME LOOSE, INSTALLED NEW RUBBER DUCT, LEAK CHECKED GOOD. CLEANED AND REINSTALLED CABIN O2 MASK. DURING FUNCTIONAL CHECK FOUND 20 DEF AND 26 DEF PSU DOOR DID NOT DROP. CLEANED PAINT FROM LATCH AND LUBED LOCK PIN AT PSU 20 DEF AND REMOVED AND REPLACED PSU PANEL AT ROW 26 DEF.