What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND PASSENGER DOOR CUTOUT REPAIR NOT DONE IAW DC9 SRM 53-05 FIG 26A. INSTALLED NEW REPAIR IAW DC9 SRM 53-05 FI G 26A AND REO-L00142.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND PASSENGER DOOR CUTOUT REPAIR NOT DONE IAW DC9 SRM 53-05 FIG 26A. INSTALLED NEW REPAIR IAW DC9 SRM 53-05 FI G 26A AND REO-L00142.