What was found
FOUND LIGHTNING STRIKE BLENDED BEYOND LIMITS AT RIGHT HAND WINDOW PANEL, BS 775 - 813. FABRICATED, DRILLED AND INSTALLED REPAIR DOUBLER IAW REO L00173.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND LIGHTNING STRIKE BLENDED BEYOND LIMITS AT RIGHT HAND WINDOW PANEL, BS 775 - 813. FABRICATED, DRILLED AND INSTALLED REPAIR DOUBLER IAW REO L00173.