What was found
DURING A SCHEDULED INSPECTION, FOUND FORWARD ENTRY FLOOR SUPPORT AT BS 160-200 CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED NEW FLOOR SUPPORT AT BS 160-200 IAW DC9 SRM 53-01 FIG 1, 51-10-02, 51-30-02, 51-30-01, AND 53-20-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION, FOUND FORWARD ENTRY FLOOR SUPPORT AT BS 160-200 CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED NEW FLOOR SUPPORT AT BS 160-200 IAW DC9 SRM 53-01 FIG 1, 51-10-02, 51-30-02, 51-30-01, AND 53-20-01.