What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND AFT CARGO COMPARTMENT FLOOR SUPPORT FITTING ON STRINGER 27L CORRODED AT BS 897. REMOVED AND REPLACED SPLICE SUPPORT FITTING IAW DC9 SRM 53-11-03, 51-10-04, AND 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND AFT CARGO COMPARTMENT FLOOR SUPPORT FITTING ON STRINGER 27L CORRODED AT BS 897. REMOVED AND REPLACED SPLICE SUPPORT FITTING IAW DC9 SRM 53-11-03, 51-10-04, AND 51-30-02.