What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND AFT PIT CARGO DOOR SIDE WAY SCUFF PLATE CORRODED BEYOND LIMITS. INSTALLED NEW SCUFF PLATE IAW DC9 SRM 51-10-02 AND 51-10-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND AFT PIT CARGO DOOR SIDE WAY SCUFF PLATE CORRODED BEYOND LIMITS. INSTALLED NEW SCUFF PLATE IAW DC9 SRM 51-10-02 AND 51-10-04.