What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LONGERON 6R CRACKED AT BS 680. CORRECTIVE ACTION: FABRICATED AND INSTALLED REPAIR SPLICES IAW DC9 SRM 53-02 FIG 18 AND 57-10-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND LONGERON 6R CRACKED AT BS 680. CORRECTIVE ACTION: FABRICATED AND INSTALLED REPAIR SPLICES IAW DC9 SRM 53-02 FIG 18 AND 57-10-03.