What was found
FOUND FLOOR SUPPORT ANGLE AT BS 170-195 CORRODED. REMOVED OLD SUPPORT, CUT, DRILLED, TREATED, PRIMMED AND INSTALLED NEW SUPPORT IAW DC9 SRM 51-10-2, 51-30-2, 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOOR SUPPORT ANGLE AT BS 170-195 CORRODED. REMOVED OLD SUPPORT, CUT, DRILLED, TREATED, PRIMMED AND INSTALLED NEW SUPPORT IAW DC9 SRM 51-10-2, 51-30-2, 51-10-3.