What was found
FOUND CORROSION ON FLOOR SUPPORT ANGLE AT BS 160-197. REMOVED AND REPLACED, CUT, DRILLED, TREATED, AND PRIMED FLOOR SUPPORT IAW DCI SRM 53-10 FIGURE 1, 51-10-2, 53-11-1 FIGURE 13, 51-10-3, 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION ON FLOOR SUPPORT ANGLE AT BS 160-197. REMOVED AND REPLACED, CUT, DRILLED, TREATED, AND PRIMED FLOOR SUPPORT IAW DCI SRM 53-10 FIGURE 1, 51-10-2, 53-11-1 FIGURE 13, 51-10-3, 51-30-2.