What was found
FOUND AFT STAIRWAY DOOR FRAME CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED ATTACH ANGLE REPAIR IAW DC9 SRM 53-01 FIG 1, 51-30, 51-10-03, 51-10-02, 51-10-04 AND 51-30-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND AFT STAIRWAY DOOR FRAME CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED ATTACH ANGLE REPAIR IAW DC9 SRM 53-01 FIG 1, 51-30, 51-10-03, 51-10-02, 51-10-04 AND 51-30-01.