What was found
FOUND CABIN FLOOR SUPPORT ANGLES CORRODED BEYOND LIMITS AT BS 200 LBL 0-55. FABRICATED AND INSTALLED NEW FLOOR SUPPORTS IAW DC9 SRM 51-10-02, 51-10-03, 51-10-04, 51-30-01, AND 51-30-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CABIN FLOOR SUPPORT ANGLES CORRODED BEYOND LIMITS AT BS 200 LBL 0-55. FABRICATED AND INSTALLED NEW FLOOR SUPPORTS IAW DC9 SRM 51-10-02, 51-10-03, 51-10-04, 51-30-01, AND 51-30-05.