As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LOWER EMERGENCY EXIT SIGN AT AFT FLIGHT ATTENDANT STATION DOES NOT ILLUMINATE. OVERWING EMERGENCY EXIT LIGHTS INOP. REMOVED AND REPLACED EMERGENCY LIGHTING BATTERY PACK ASSY AT FS 879R IAW B717 MM 33-51-03, OPS CHECK NORMAL. RESEATED CANNON PLUG ON B5-125 BATTERY PACK, OPS CHECK GOOD PER B717 AMM 33-51.