What was found
ON GATE AFTER POST FLIGHT, RAMP REPORTS A DENT APPROX 18 INCHES IN FRONT OF REAR CARGO DOOR AT BOTTOM OF DOOR LEVEL. CLASS 3 TEMP REPAIR INSTALLED AT LONGERON RIGHT 27 FUSELAGE STATION 926 TO 948. INSPECT EVERY 3000 HRS AND REPLACE AT 8000 HRS REF 717 SRM 53-00-01. INSTALLED DOUBLER REPAIR AT LONGERON 27 RIGHT FUSELAGE 926 TO 948 IAW SRM 51-30-01 REPAIR 1. MATERIAL USED 2075 T6.075 SIZE 19 X 12.5 INCH.