What was found
DENT ON LT SIDE FUSE BETWEEN L17 AND L18 NEAR STA 229. REQUIRES REPAIR WITHIN 4500 FLT HRS AS PER SRM 53-00-01 REPAIR TO COND 3. START TIME 9538:04. INSTALLED PERMANENT DOUBLER REPAIR AT BS 213.5 TO 229 AND BETWEEN L16L AND L18L (15.5 X 14) IAW B717 SRM 53-00-01 FIG 201 REPAIR 6. MATERIAL AND SIZE USED FILLER 2024T-3.050 X 15.5 X 14.0 DOUBLER, T-3 2024 .063 X 15 X14 INCH, FINGER DOUBLER 2024T, .025 X 18 X 17 INCH.