What was found
LEFT CANTED FRAME HAS A CRACK STA 1178. INSTALLED ANGLE REPAIR ON LEFT CANTED FRAME AT STA 1178 LONG 16. MATERIAL USED 0.080 7075.0 10 .5" X 2.5" IAW B717 SRM 51-40-02 AND SRM 51-41-01. HEAT TREATED TO T-6 PER AVBORNE 98PMS.247PS.01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT CANTED FRAME HAS A CRACK STA 1178. INSTALLED ANGLE REPAIR ON LEFT CANTED FRAME AT STA 1178 LONG 16. MATERIAL USED 0.080 7075.0 10 .5" X 2.5" IAW B717 SRM 51-40-02 AND SRM 51-41-01. HEAT TREATED TO T-6 PER AVBORNE 98PMS.247PS.01.