What was found
SCHEDULED INSPECTION AT AERO CORP, FL. AFT PIT AT STA 996 SECONDARY BULKHEAD JUST UNDER FLOOR AREA AT FS 24R HAS BLOWN OUT CORROSION ON WEB. FABRICATED AND INSTALLED REPAIR IAW RES 982280, DC9 SRM 51-10-2, 51-30-2, 51-10-4 AND 51-10-3.