What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND CORROSION OUT OF LIMITS AND LEVEL 2 CORROSION AT THE FORWARD CARGO PIT COMPARTMENT AT STA 517 L-27R AND STA 218 L-29L. REMOVED CORROSION OUT OF LIMITS, FABRICATED AND INSTALLED NEW FLOOR CHANNEL AND LONGERON SECTION IAW DC9 SRM 51-30-2, 51-10-3, 51-10-4, 53-02 FIG 18.