What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND TWO DENTS TO CLOSE TO EACH OTHER AND CREASED OUT OF LIMITS AT STA 882 AND STA 884 L-24R. CUT OUT CREASED AREAS AT STRINGER, FABRICATED, TREATED, AND PRIMED DOUBLERS IAW DC9 SRM 53-04 FIG 12B, 51-10-3, AND RES NR 982225 AND NR 982294.