What was found
SCHEDULED INSPECTION AT AERO CORP, FL. LOWER FACE ON UPPER PRESSURE PANEL IN NOSE WHEEL WELL HAS CORROSION ON INSULATION SUPPORT MOUNT BRACKETS AT STA 71 16 LEFT TO RIGHT OF CENTER, STA 73 TO 78 16 LEFT TO CENTER, STA 80 TO 99 16 FROM LEFT TO RIGHT CENTER. REMOVED AND REPLACED SUPPORT MOUNT BRACKETS, DRILLED, TREATED, PRIMED AND INSTALLED IAW DC9 SRM 51-30-2, 51-10-2, 51-10-4, 51-10-3. (P/N 1A-41574-1), (P/N 1A-41574-2), (P/N 1A-41574-3), (P/N 1A-41572-1), (P/N 1A-41571-1), AND (P/N 1A-41570-1).