What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND INTERCOSTALS TO BE CORRODED AND OUT OF LIMITS AT STA 945 L-29R AND STA 976 TO 996 L-27L. REMOVED AND REPLACED, FABRICATED, INSTALLED, AND PRIMED NEW INTERCOSTALS IAW DC9 SRM 51-10-4, 51-30-2, 51-10-3, 51-30-5, AND 51-10-2.