What was found
SCHEDULED INSPECTION AT AERO CORP, FL. CORROSION WAS FOUND UNDER THE AUXILIARY TANK JUST FORWARD OF THE RIGHT HAND KIDNEY PANEL AT STA 559. REMOVED ALL CORROSION AND DOUBLER, FABRICATED AND INSTALLED NEW REPAIR DOUBLER AND REPLACED END CAP FITTING IAW DC9 SRM 51-30-2, 51-30-5, 51-10-4, AND 53-01 FIG 1. END CAP (P/N 3924809-501N).