What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND CREASE AT STA 218 L-18-19L AND A DENT AT STA 220 L-18-19L BOTH OUT OF LIMITS. COLD WORKED DENTS, FABRICATED INTERNAL DOUBLER REPAIR, DRILLED, COUNTERSUNK, DEBURRED, TREATED, PRIMED AND INSTALLED INTERNAL REPAIR IAW DC9 SRM 51-10-4, 51-30-2, 53-04 FIG 38, RES NR 99189 AND 99234.