What was found
SHEDULED INSPECTION AT AERO CORP, FL. FOUND FORWARD CARGO PIT CEILING CENTER LINE AT STA 503 INTERCOASTAL CRACKED AT FOUR WAY TIE SUPPORT. FABRICATED REPAIR, HEAT TREATED, DRILLED, DEBURRED, ALODINED, PRIMED, AND INSTALLED IAW DC9 SRM 51-30-2, 53-11-2 FIG 4, 51-10-2A, 51-10-4, 51-10-3, 51-30-2, AND RES NR 99197.