What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND DENTED FUSELAGE SKIN AT STA 437, 2 BELOW L-24R. CUT OUT DENTED SECTIONS, FABRICATED NEW SKIN SECTION AND REPAIR SPLICES IAW DC9 SRM 53-04 FIG 30, 51-10-2, 51-10-3, 51-10-4 AND RES NR 9920. (P/N 105846-1) ON, (P/N 59204195) OFF.