What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND DENTED AREA AT STA 968 L-26R CREASED AND OUT OF LIMITS. CUT OUT DENTED AREA, FABRICATED AND INSTALLED REPAIR DOUBLER, FINGER DOUBLER, SKIN SPLICES, STRINGER SPLICES, SHEAR TIES IAW DC9 SRM 53-04 FIG 16 AND RES NR 9940, 9922 AND 99284.