What was found
SCHEDULED INSPECTION AT AERO CORP, FL, FOUND THE FORWARD PIT NR 2 AND NR 3 LOWER SIDE WALL PANEL HAS A 4 CRACK AND 8 HOLE. REMOVED, REPLACED, FABRICATED, TRIMMED, AND DRILLED NEW PANELS IAW DC9 SRM 51-30-0, 53-21-0, MM 25-52-1, AND RES NR 982221.