What was found
SCHEDULED INSPECTION AT AERO CORP, FL, FOUND FORWARD PIT FLOOR PANELS AT STA 351-503, FORWARD PIT AFT BULKHEAD LEFT AND RIGHT PANEL, FORWARD CARGO PIT FLAP VALVE AT STA 595 L-29-30, AND FORWARD CARGO FLOOR SUPPORT AT STA 218-237 WITH CORROSION, ELONGATED HOLES AND MISDRILLED HOLES. CUT, DRILLED, TRIMMED, FABRICATED, DEBURRED, ALODINE AND PRIMED PANELS, FLOOR SUPPORT, WEB, AND REINSTALLED FLAP VALVE IAW DC9 SRM 51-04-4, 53-21-0 FIG 7A, 51-10-4, 51-10-3, 51-20-2, 51-10-2 PAGE 2, 51-10-1, AND MM 21-32-8. FLAP VALVE P/N OFF 5713641-5, FLOOR SUPPORT P/N 1A-41829-1, PANEL P/N 1A-41838-1.