What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND CORROSION BULGED AT STA 937 L-26R. MECHANICALLY REMOVED CORROSION, FASTENERS AND DOUBLER. FABRICATED AND INSTALLED FASTENERS, DOUBLER IAW DC9 SRM 51-30-5, 51-30-2, 51-20-0, AND RES NR 99301.