What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND VARIOUS LOCATIONS WITH CORROSION. FIRST, AT STA 602 LONGERON L-29L. SECONDLY, THE AFT PIT FORWARD SIDE AT STA 382 BETWEEN L-29R TO L-27L. THIRD, THE LEFT LAVATORY BULKHEAD LOWER PORTION AT STA 965. LAST, CORROSION AROUND FASTENERS HOLES ON THE FLOORBEAM AT STA 996. REMOVED AND REPLACED FASTENERS, CLEANED CORROSION, REMOVED DAMAGE FRAME SECTION, FABRICATED ANGLES, LONGERON, HEAT TREATED, PRIMED, AND INSTALLED ALL PARTS IAW DC9 SRM 51-10-2A, 51-10-3, 51-30-5, 51-30-2, 51-10-4, 51-10-1, 51-20-0, 53-05 FIG 20A. SPLICE (P/N 1A-34249-2) OFF, ANGLE (P/N 52912758-12000).