What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND A CREASE OUT OF LIMITS AT STA 484 RIGHT SIDE L-19-20. ALSO, A COAX CABLE STAND OFF BROKEN AT STA 955 ABOVE L-20R. TRIMMED OUT CREASE, FABRICATED AND INSTALLED DOUBLER IAW DC9 SRM 51-30-5, 51-30-2, 53-04 FIG 12B, AND RES NR 99293. ALSO, REMOVED, REPLACED AND FABRICATED NEW STAND OFF AT STA 955 (P/N 1A-42054) IAW DC9 SRM 51-10-4, 51-10-2, 51-30-2 AND RES NR 99255.