What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND A DENT OUT OF LIMITS AT STA 361R L-28R. REMOVED FASTENERS, COLD WORKED DENT, HFCE INSPECTED DENT WITH NO CRACKS NOTED. FABRICATED DOUBLER, FINGER DOUBLERS, DRILLED, COUNTERSUNK, DEBURRED, TREATED, PRIMED, AND INSTALLED IAW DC9 SRM 53-04 FIG 38, 51-10-2, AND RES NR 99203.