What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND FLOOR TRACKS AT THE AFT PIT STA 756 TO 780 AND ON THE RIGHT LOWER SIDE AT STA 935 TO 996 WITH CORROSION. MECHANICALLY REMOVED CORROSION, FABRICATED NEW SECTION OF FLOOR TRACKS, DRILLED, DEBURRED, COUNTERSUNK, TREATED AND PRIMED IAW DC9 SRM 51-10-3, 51-10-4 AND 53-05-3.