What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE FORWARD CARGO PIT DOORWAY CRACKED AT STRINGER 21R. FABRICATED Z CHANNEL REPAIR AND DOUBLER, REINSTALLED T ANGLE AND INTERCOSTAL IAW SB 737-53-1051 AND RES NR 99142.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE FORWARD CARGO PIT DOORWAY CRACKED AT STRINGER 21R. FABRICATED Z CHANNEL REPAIR AND DOUBLER, REINSTALLED T ANGLE AND INTERCOSTAL IAW SB 737-53-1051 AND RES NR 99142.